Sign In | Join Free | My entremaqueros.com
China Shenzhen Wisdomlong Technology CO.,LTD logo
Shenzhen Wisdomlong Technology CO.,LTD
Shenzhen Wisdomlong Technology CO.,LTD Work hard and best service for you!
Verified Supplier

8 Years

Home > Redundant Power Supply Module >

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10

Shenzhen Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10

Brand Name : Schneider

Model Number : 140DAO84210

Place of Origin : FR

MOQ : 1

Price : negotiable

Payment Terms : T/T, Western Union

Supply Ability : 100

Delivery Time : 2-3 work days

Packaging Details : New in original box

Brand : Schneider

Model : 140DAO84210

Palce of Origin : FR

Series : Quantum I/O

Module Format : Standard

Voltage drop : 1.5V

Discrete output number : 16

Contact Now

Redundant Power Supply Module SCHNEIDER AUTOMATION 140-DAO-842-10 OUTPUT MODULE 140DAO84210

Specifications

Manufacturer: Modicon Quantum
Series: Quantum I/O
Weight: Ask
Product or component type: AC discrete output modules
Discrete output number: 16
Group of channels: 4 groups of 4 channels
Supply frequency: 47...63 Hz
Voltage drop: 1.5 V
Discrete output voltage: 83...253 V AC
Addressing requirement: 1 output word
Absolute maximum output: 400 Vrms 1 cycle AC
300 Vrms for 10 s AC
Minimum load: 5 A
Minimum load current: 4 A rms per group
4 A rms 85...132 V per output
3 A rms 170...253 V per output
2.5 mA rms 230 Vrms off state leakage per output
2 mA rms 115 Vrms off state leakage per output
16 A rms per module
1 mA rms off state leakage per output
Surge current: <= 45 A during 1 cycle per group
<= 30 A during 2 cycles per group
<= 30 A during 1 cycle per point
<= 25 A during 3 cycles per group
<= 20 A during 2 cycles per point
<= 10 A during 3 cycles per point
DV/Dt: 400 V/ms
Response time: <= 0.5 ms at state 1 to state 0
<= 0.5 ms at state 0 to state 1
Fault indication: Blown fuse
Loss of field power
Protection type: Internal by RC filter
Internal output protection by 5 A fuse
Power dissipation: 1.85 + (1.1 V x total module load current)
Marking: CE
Local signalling: 16 LEDs green input status
1 LED red external fault detected (F)
1 LED green bus communication is present (Active)
Bus current requirement: 350 mA
Module format: Standard

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279

Similar Products

140ACI03000

140ACI04000

140ACO02000

140ACO13000

140ARI03010

140AMM09000

140AVI03000

140AVO02000

140ATI03000

140DDI35300

140DDI84100

140DDI85300

140DAI74000

140DAI75300

140DAO85300

140DAO84000

140DAO84210

140DDO35300

140DDO84300

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10

Estimated Shipping Size
Dimensions: 2" x 4" x 10" (5 cm x 10 cm x 25 cm)
Weight: 1 lbs 2 oz (0.51 kg)

Schneider 140-DAO-842-10 Output Module 140DAO84210 Sealed

PN: 140-DAO-842-10
140DAO84210

Schneider Automation Inc
PN: 140 DAO 842 10
140DAO84210
Output Module

AC Out 100-230V 4X4
TSX Quantum
112698
UPC Number: 3 595861 126985

PV: 00
RL: 77
DOM: 03-2002


Sealed In Factory Packaging

SIL
NOTE: For complete definitions and parameters related to SIL ratings refer to IEC 61508, "Functional safety of electrical/electronic/programmable electronic safety related systems". Provided here is a partial definition.


safety integrity level
discrete level (1 out of a possible 4) for specifying the safety integrity requirements of the safety functions to be allocated to the E/E/PE safety-related systems, where safety integrity level 4 has the highest level of safety integrity and safety integrity level 1 has the lowest


(Definition IEC 61508)
SIL2 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651 60S V1.00 or 140 CPU 671 60S V1.00) to implement Safety Functions in a Safety-Related System.


SIL3 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651 60S V2.00 or 140 CPU 671 60S V2.00) to implement Safety Functions in a Safety-Related System.


SIR
Safety Integrity requirement
Safety Integrity requirements are derived from a risk assessment and describe the likelihood of a Safety Function to be performed satisfactorily, for instance the degree of certainty necessary for the Safety Function to be carried out.


sniffingreading the configuration out of a PLC


SRS
safety requirements specification
specification containing all the requirements of the safety functions that have to be performed by the safety-related systems
(Definition IEC 61508)


Product Tags:

analog interface module

      

plc power supply module

      
 Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10 Manufactures

Output Redundant Power Supply Module SCHNEIDER Automation 140-DAO-842-10 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wisdomlong Technology CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)