Redundant Power Supply Module GE Fanuc IC200MDL940 OUTPUT RELAY ISOLATED 2A FORM A 16PT
   
   
   
  Module Characteristics
  Points IC200MDL930: 8 individually isolated Form A relay outputs
            IC200MDL940, BXIOOR162: 16 individually isolated Form A relay outputs
 Module ID IC200MDL930: FFFF8040
                 IC200MDL940, BXIOOR162: 80408040
  Isolation:
 User input to logic (optical) and frame ground: 250VAC continuous; 1500VAC for 1 minute
 IC200MDL930: Group to Group: not applicable
 IC200MDL940, BXIOOR162: Group to group: 250VAC continuous; 1500VAC for 1 minute
 Point to point:: 250VAC continuous; 1500VAC for 1minute
 LED indicators One green LED per point shows individual point on/offstate
                         OK LED indicates backplane power is present Backplane currentconsumption
                         IC200MDL930: see graph
                         IC200MDL940, BXIOOR162, 5V output:: 490mA maximum
 External power supply 0 to 125VDC, 5/24/125VDC nominal
                                     0 to 265VAC (47 to 63Hz), 120/240VAC nominal
  Thermal derating None
   
   
   
   
  Output Characteristics
  Output voltage 0 to 125VDC, 5/24/125VDC nominal
                         0 to 265VAC (47 to 63Hz), 120/240VAC nominal
 Output voltage drop 0.3V maximum
 Load current 10mA per point minimum
 2.0A for 5 to 265VAC maximum (resistive)
 2.0A for 5 to 30 VDC maximum (resistive)
 0.2A for 31 to 125 VDC maximum (resistive)
 Output leakagecurrent Not applicable (open contact)
 On response time  10ms maximum
 Off response time  10ms maximum
 Protection No internal fuses or snubbers
 Switching frequency 20 cycles per minute (inductive load)
 Relay type Fixed coil, moving armature
 Contact type Silver alloy
   
   
   
   
   
   
   
   
    IC3600EPSX1 12V LAMP REGULATOR IC3600EPSX
 IC3600EPSY1 REGULATOR BOARD IC3600EPSY
 IC3600EPZU1 POWER SUPPLY CARD
 IC3600KHDA2 RELAY BOARD
 IC3600KHDB2 RELAY BOARD
 IC3600KHDC2 RELAY BOARD
 IC3600KHVA1 RELAY BOARD
 IC3600KHVA2 RELAY BOARD
 IC3600KHVB2 RELAY BOARD
 IC3600KHVD2 RELAY BOARD
 IC3600KMRA2 MEDIUM-DUTY-RELAY
 IC3600KMRA5 MEDIUM DUTY RELAY
 IC3600KMRA6 MEDIUM-DUTY-RELAY
 IC3600KMRA9 RELAY
 IC3600KMRB1 MEDIUM-DUTY-RELAY
 IC3600KMRB2 RELAY
 IC3600KMRB3 MEDIUM-DUTY-RELAY
 IC3600KMRB5 MEDIUM-DUTY-RELAY
 IC3600KMRB6 RELAY, ALT P/N: L8934 (COMMUNICATIONS INST
 IC3600KMRB9 RELAY
 IC3600KMRC1 MEDIUM-DUTY-RELAY
 IC3600KMRC2 MEDIUM-DUTY-RELAY
 IC3600KMRC5 RELAY
 IC3600KMRC6 MEDIUM-DUTY-RELAY-MI
 IC3600KMRC9 RELAY
 IC3600KMRCD RELAY
 IC3600KMRD2 MEDIUM-DUTY-RELAY
 IC3600KMRD5 MEDUIM DUTY RELAY
 IC3600KMRD6 MEDIUM DUTY RELAY
 IC3600KMRD9 MEDIUM-DUTY-RELAY
 IC3600KMRDD
 IC3600KMRE2 MEDIUM-DUTY-RELAY
 IC3600KMRE3 MEDIUM-DUTY-RELAY
 IC3600KMRE5 MEDIUM-DUTY-RELAY
 IC3600KMRE6 MEDIUM-DUTY-RELAY
 IC3600KMRE9 MEDIUM-DUTY-RELAY
 IC3600KMRF2 MEDIUM-DUTY-RELAY
 IC3600KMRF5 MEDIUM DUTY RELAY
   
   
   
  Relay output module IC200MDL930 provides 8 individually-isolated Form A relay outputs.
 Relay Output Modules IC200MDL940 (shown below) and BXIOOR162 provide 16 individually-isolated Form A relay outputs.
 The contact is closed when the host CPU is active and the corresponding output logic bit is “1”.
   
   
   
   
  Power for module operation comes from the backplane. Loads must be powered by an external source.
 Intelligent processing for this module is performed by the CPU or NIU.
   
   
  LED Indicators
  Individual green logic-side LEDs indicate the On/Off status of each output point. The output LEDs are logic-driven and independent of load conditions.
 The green OK LED is ON when backplane power is present to the module.
   
   
  Preinstallation Check
  Carefully inspect all shipping containers for damage. If any equipment is damaged, notify the delivery service immediately. Save the damaged shipping container for inspection by the delivery service. After
 unpacking the equipment, record all serial numbers. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system.
   
   
  Installation in Hazardous Locations 
  • EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B,
 C, D OR NON-HAZARDOUS LOCATIONS ONLY
 • WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;
 • WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND
 • WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
   
   
  For module IC200MDL930, if additional bussed terminals are needed, the B terminals can be made available by using a shorting bar. The shorting bar has a maximum current-carrying capacity of 2 Amps per point. See chapter 2 of the VersaMax I/O System Manual, GFK-1504, for more information
 When wiring outputs to inductive loads, use of external suppression circuits is recommended. See chapter 2, “Installing Wiring for I/O
 Devices-Wiring to Inductive Loads” in the VersaMax I/O System Manual, GFK-1504, for more information.
   
   
  Row B connections are for 16-point modules only.
   
   
     
  Side B connections are for 16-point modules only.
   
   
     
   
  The module’s backplane 5 volt power requirement increases as the number of points that are simultaneously on increases. The chart below shows the relationship between the number of points on and the maximum current required.
   
   
   
  Operating Note
 If hot insertion of a module is done improperly, the operation of other modules on the same backplane may be disrupted. See Installing a
 Module on a Carrier in the VersaMax Modules Manual, GFK-1504.
   
     
   
     
     
   
   
   
   
 OTHER SUPERIOR PRODUCTS
    	 		 			| Yasakawa Motor, Driver SG- |  			Mitsubishi Motor HC-,HA- |  		
 		 			| Westinghouse Modules 1C-,5X- |  			Emerson VE-,KJ- |  		
 		 			| Honeywell TC-,TK- |  			GE Modules IC - |  		
 		 			| Fanuc motor A0- |  			Yokogawa transmitter EJA- |  		
 	 
     
   
   
  Contact person: Anna
  E-mail: wisdomlongkeji@163.com
  Cellphone: +0086-13534205279
              
        
            
                
                                    Product Tags:
                                              
                                          
                                
                
                    
                                             
                                         | 
                
                
                    | 
                         
                             
                                                                Diode Redundancy Module IC200MDL940 Output Relay Isolated 2A FORM A 16PT Images
                                                            
                        
                     |